background image

‘华东六省一市造纸学会第二十一届学术年会》暨‘江苏省造纸学会第九届学术年会’论文集

造纸废水处理调节池容积研究.

施英乔丁来保孙玉房桂干

(中国林业科学研究院林产化学工业研究所,南京市,210042)

摘要:连续两月监测了某化学机械浆制浆有限公司每小时的废水发生量。结果表明:吨浆废水发生量为34.72 m3,波

动范围为24寸/t~55

m'/t,吨浆排放废水量仅及国家规定排放量的1/6。废水发生量的时变化系数1.79,总变化系数是2.86,

总变化系数比市政污水高50%.研究分析了最大日废水量(3740m3)时变化曲线,从而确定调节池的最小容积为732m3.

关键词:调节池化机浆废水变化系数

Research

on

the

Adj

ust

Tank Volume for Treat

effluent

of

BCTMP

pulping

Shi Yingqiao

Ding Laibao

Sun Yu

Li Ping

Fnng Guigan

(.Institute

ofChemical Industry ofForest

Products,CAF,Sanjing 210042)

Abstract:In this research

we

supervised the amount of effluent of

an

CTMP pulping

company

continuously for

two

months.The results indicated that the

amount

of

effiuent

is about 34.72m3/pulp.the

range

is about

2 4

m3/t

5 5

m3/t.The

amount

of

emuent

is

iust

1/6 of the standard of nation.The variable

coe伍cient

of

water

amount

is 1.79。total variable coefficient is 2.86。the total variable

coe伍cient

is

50%higher

than the

coe伍cient

of

govemment.After analyzing the variable curved line when the

water

amount

is

highest,we

determined the

minimum volume of

adiust

tank is 732m’.

Key

words:

adjust

tank;

emuent ofAPMP;

variable

coefficient

化学机械制浆作为一种清洁生产新技术正在我国快速发展,化学机械制浆废水的处理研究和工程设计

也已成为造纸工业行业环境保护技术发展的一项新内容。在化学机械制浆废水处理工程设计时,必须掌握

废水的发生量和流量变化系数。一般制浆造纸废水的波动比城市污水大,这种变化对废水处理设施,特别

是对生物处理构筑物正常发挥净化功能是不利的Ⅲ。但到目前为止,尚未见到设计手册或研究文献中关于

制浆造纸企业化学机械浆废水流量变化系数的报道,这给工程设计带来一定困难。为此,我们在为某制浆

有限公司化学机械制浆BCSMP废水处理工程设计中,连续两月实地监测了该类废水的发生量和日、时、总

流量变化系数,并进行了归纳分析。本文对需要了解化学机械制浆造纸企业废水发生量及其变化系数,特

别是对制浆造纸废水处理工程调节池的设计具有实用参考意义。

1废水发生量

该公司以速生材杉木为主要原料,采用现代化学热磨机械制浆(BCTMP)工艺,生产市场紧俏的高档

卫生纸用浆。2

0 0

6年5月和6月,在现场连续两个月每小时监测了废水的发生量,结果见表1。表l

显示,两个月的吨浆废水发生量非常接近,分别为34.76 m3/t和34.69 m3/t,平均为34.72 m3/t,而造纸

工业水污染物排放国家标准GB3544—2001中规定漂白木浆废水限量为220 ms/t。可见,化学热磨机械制浆

(B∞皿)吨浆排放废水量仅及国家规定排放量的1/6左右,显示出化学机械制浆作为清洁生产工艺的一