一、21VF群控
21VF群控分几种情况,B梯底层和顶层各少一层,C梯底层少二层,D梯底层少一层。
下面以5层为例,说明群控设置。
1、安装参数
Name
Group
Description
Setting
RCB-NO
1
Car Identifier 群控梯号
1 to 8 = car A to H
Car identifier in group
N/A
BOTTOM 2
Bottom Landing Position 最底层
1 to 64 = landing 1 to 64
The bottom landing position the car is capable of reaching.
TOP
2
Top Landing Position 最高层
1 to 64 = landing 1 to 64
The top landing position the car is capable of reaching.
LOBBY
2
Lobby Landing Position 基站
1 to 64 = landing 1 to 64
Lobby position for car
GROUP
4
Number Of Cars In Group 群控电梯总数
1 to 8 = 1 to 8 cars in group
Defines number of cars in group.
EFO-P
6
EFO Return Landing Position 消防楼层
1 to 64 = landing 1 to 64, opens front door
101 to 164 = landing 1 to 64, opens rear door
201 to 254 = landing 1 to 54, opens both doors
Main SES recall landing.
EFO-CK
6
EFO Return Landing Position Check 消防楼层检查
1 to 64 = landing 1 to 64, opens front door
101 to 164 = landing 1 to 64, opens rear door
201 to 254 = landing 1 to 54, opens both doors
Check for EFO-P parameter
5
4
3
2
1
OCSS楼层数
3
2
1
5
4
3
2
1
3
2
1
4
3
2
1
3
2
1
-1
-2
楼层显示
MCSS 楼层数
A
B
C
D