SNCI∥SCR联舍脱硝技术
[摘
要]
[关键词]
[中圈分类号]
[文献标识码]
[文章编号]
IDOl编号]
在4
1
0
t/h编炉丘的应用
周国民,赵海军,龚家猷,王松峰
国华北京热电分公司,北京
100025
介绍某电厂410 t/h燃煤锅炉SNCR/SCR联合脱硝系统的脱硝原理、基本构成及应用
效果。对运行中出现的如尿素溶液喷孔下方水冷壁腐蚀、冷灰斗积渣、氨分布不均等问
题进行分析并采取措施予以防范。测试结果表明,在NU浓度为247~318
mg/m3的
情况下及氨逃逸量不大于5 t-tL/L时.SNCR/SCR联合脱硝系统脱硝效率大于80%。
选择性非催化还原(SNCR);选择性催化还原(SCR);燃煤锅炉;脱硝;Nq排放
TK267
B
1002—3364(2011)03—0058一04
10.3969/j.issn.1002—3364.201
1.03.058
APPLICATIoN oF HYBRID DENITRIFICATIoN TECHNOLOGY
SNCR&SCR ONTO 410
t/h
BOILER
ZHOU
Guomin,ZHA0 Haijun,GONG
Jiayou,WANG
Songfeng
Guohua Beijing Thermal Power Branch Company,Beijing 100025,PRC
Abstract:The denitrification
principle,basic
structure,and effectiveness in application of hybrid denitri—
fication techonology
SNCR&SCR
on
4
1 0
t/h coal—fired
boiler in
one
power plant have been
presen—
ted,the problems occurred in operation,such
as
corrosion of water—wall below spraying
hole
of
car-
bamide solution.deposit of slags in water—cooled ash hopper,and
non—uniform
distribution of ammo—
nia etc.,being analysed,and preventive measures being adopted.Results of
test
show that the denitrifi—
cation
efficiency
of said hybrid denitrification techonology is
greater
than
80%under
condition of NOz
concentration being
247~318 mg/m3。and
the
escape
of zmmonia isn’t
greater
than 5
ttL/L.
Key words:selective non—catalytic reduction(SNCR);selective catalytic
reduction(SCR);coal—fired
boiler;denitrification;NOz emission
目前,控制Nq排放的技术措施分为两类,一类
是低氮燃烧控制技术‘H3,另一类为烟气净化技术,即
把烟气中己生成的Nq还原为Nz,其主要包括选择
性非催化还原技术(SNCR)和选择性催化还原(SCR)
技术等嘲。
SNCR/SCR联合脱硝技术,是将SNCR技术与
SCR技术联合应用,即在炉膛上部850---1 100℃的高
温烟气区域对Nq进行脱除,然后在锅炉尾部利用较
,=;=========■=}==================
作者简介:
周国民(1976一),男.内蒙古开鲁人,浙江大学工程热物理专业工学硕士.现为神华国华国际电力股份有限公司北京热电分公司工程
E—mail:
师。主要从事电站锅炉优化运行、系统改造及管理等。
zhouguomin718@163.corn
1032772@ghepc.tom
发电技术论坛
热力发电.二o=