background image

变频电机噪声分析与计算

赵文辉,冯嫦杰

无锡哈电电机有限公司,江苏无锡( 214000)

摘 要 简述了电机噪声的产生原因,以两个不同型号的变频异步电机为例,给出电机空气

动力噪声的计算方法。通过对电机噪声试验值与理论计算值的对比分析,总结出抑制电机噪声,
特别是空气动力噪声的有效措施,为电机设计提供理论依据。

关键词 异步电机; 电磁噪声; 空气动力噪声

中图分类号: TM301. 4

+

3

文献标识码: B 文章编号: 1008-7281( 2011) 06-0044-03

Analysis and Calculation on Noise of Variable-Frequency Motor

Zhao Wenhui and Feng Changjie

Abstract

This paper briefly describes the causes of motor noise. Taking two types of var-

iable-frequency induction motors as examples,this paper gives the method to calculate aerody-

namic noise of motor. By comparative analysis between the test value and calculation value of

noise,the effective measures to inhibit noise of motor,especially for aerodynamic noise are

summed up. It can provide a theoretical basis for design of motor.

Key words

Induction motor; inhibition of electromagnetic noise; inhibition of aerodynam-

ic noise

0

引言

噪声是社会的一大公害,它污染环境,给人类

健康带来极大的危害。电机是一种噪声源,它的噪
声水平已被列为衡量电机质量的一项重要指标,成
为影响其在市场上竞争能力的一个重要因素。

随着用户环保意识的增强,用户对电机噪声

的要求也越来越高,如何有效的降低电机噪声,常
规电机可通过试验积累经验,非常规电机则需要
在设计阶段给与一定的计算指导。本文以两台不
同型号的异步变频电机为例,阐述了电机噪声的
产生原因、计算方法及降低措施。

1

电机基本技术参数

1. 1

YPKK450-4 600kW 400V

变频异步电机技

术参数

电 机 型 号 YPKK450-4,功 率 600kW,电 压

400V,

调速范围 1 430 /2 000r / min,电机三圆 760 /

500 /280mm,

气隙 2. 4mm,铁心总长 492mm,定子

风道 9 × 8mm,转子风道 8 × 8mm。电机的冷却方
式 IC616,冷却器内加有吸音材料,内风路采用径
向离心风 机,离 心 风 扇 参 数: 外 径 770mm,内 径

440mm,

叶片宽度 97mm,叶片个数为 12。外风路

采用轴流风机,轴流风扇参数: 外径 630mm,内径

210mm,

叶片宽度 120mm,叶片个数为 4。内外风

机的同步转速都为 1 500r / min。

电机在高转速下测量的声压级噪声: 关闭外

风机时电机噪声为 83. 4dB( A) ,开外风机时电机
噪声为 84. 8dB( A) 。

1. 2

YPKS560-6 1100kW 690V

变频异步电机技

术参数

电机 型 号 YPKS560-6,功 率 1 100kW,电 压

690V,

调速范围 960 /1 380r / min,电机三圆 960 /

700 /475mm,

气隙 2. 7mm,铁心总长 592mm,定子

风道 11 × 8mm,转子风道 11 × 8mm。电机的冷却
方式 IC86W,冷却器内加有吸音材料,内风路采用
径向离心风机,离心风扇参数: 外径 600mm,内径

348mm,

叶片宽度 188. 5mm,叶片个数为 12,风机

的同步转速为 1 500r / min。

电机 在 高 转 速 下 测 量 的 声 压 级 噪 声 为

79. 4dB( A) 。

2

电机的噪声产生的原因

电机的噪声大致可分为三类: 电磁噪声、机械

4

4