background image

净水技术201 1,30(3):72—77

Water

Purification Technology

松江二水厂深度处理改造方案及净水效果

冯钧,陶明,徐建平

(上海松江自来水公司,上海201600)

要为使出厂水达到新颁《生活饮用水卫生标准》(GB 5749---2006)的要求,松江自来水公司二水厂将水平沉淀池改造为短

水平沉淀池、斜管沉淀池及上向流活性炭滤池,利用两组沉淀池之间的空间安装臭氧设备。在节能、节地条件下,实现了臭氧生

物活性炭水处理工艺。提高了出厂水水质。

关键词臭氧活性炭斜管沉淀池深度处理

中图分类号:TU991.2

文献标识码:A

文章编号:1009--0177(2011)03--0072--06

Rehabilitation

Scheme

and

Water

Purmcation

E仃bct of Advanced

Treatment

Processes for

Songjiang

No.2

Water

Treatment

Plant

Fe呜Jun,Tao Ming,Xu

Jianping

(Shanghai肋蟛妇增Water

Works

Company,Shanghai

201600,吼打圳

Abstract

In order

to

meet the

flew

drinking

water

standards,the

Songjiang

No.2

Water

Treatment Plant reconstructed the

coNveH-

tional horizontal—flow sedimentation basin into

short

horizontal—flow sedimentation

basin.肌inelined—tube

sedimentation basin and

all

up-flow GAC filter.To realize the goal of land and energy saving,an

ozone-BAC

advanced

treatment system

W88

designed

and

es-

tablished.The effluent quality

WSS

improved.

Key words

ozone

activated carbon

inclined-tube sedimentation basin

advanced treatment processes

松江自来水公司第二水厂(以下简称松江二水

厂)原水取自黄浦江上游支流斜塘,近年来水质受

到定程度污染。松江二水厂原有常规处理工艺,不

能将受污染原水净化达到《生活饮用水卫生标准》

(GB

57州006)的要求,尤其是COD超标比例较

高。2007年,松江自来水公司开始酝酿对其净水工

艺进行深度处理改造,以确保供水水质在新标准所

要求的最后期限前达橱¨。

1松江二水厂原有水质净化工艺及

净水效果

1.1原有常规处理工艺流程

松江二水厂规模为20万mVd,是松江供水区

域内主要水厂,其日均供水负荷已达80%。该水厂

包括2条lO万mJ/d生产工艺流程。均为常规水处

【收稿日期】2010-09--08

【作者简介1冯钧(1969一),男,本科,高级工程师。

电话:021-57705710;E—mail:zls-sj@vip.163.啪。

一72一

理工艺,原水取水后经约10 km管道输送至水厂,

预加氯约2 mg/L后投加聚合氯化铝,经管道混合

器后经絮凝反应池、平流沉淀池和气水反冲洗滤

池,再经清水库加氯消毒后由二泵房送入供水管

网,其净水工艺流程见图l。

1.2斜塘原水水质

由于流域多年来的经济发展,斜塘原水水质有

逐年下降趋势。

表I是松江二水厂2007。2009年部分原水水

质指标汇总。从表l中可以看出,斜塘原水COD叭

氨氮较高,其中CODM.最高超1l

ms/L,氨氮最高达

到5.6 mg/L,表明水体受到一定程度有机污染。此
外原水中铁、锰浓度也较高,铁最高达9 mg/L,年度

平均2 mg/L左右。此外,由于斜塘属于太湖一淀山

湖一黄浦江水系,湖泊水带来一定量藻类,在适宜季

节沉淀池内藻类大量繁殖,给净水效果造成影响。

1.3常规工艺条件下出厂水水质

表2为松江二水厂2007—2009年部分出厂水

万方数据