background image

电气工程

Electric Works

一、工艺流程图

  Technological process Diagram

二 、 电 气 安 装 质 量 控 制 点 及 控 制 措 施

    Quality  Control  Point  and  Control 

Measure on Electric Installation

分项工程

Sub-item 

质量控制点

Quality Control Point

质量控制措施

Quality Control Measure

备注

Remark

施 工 准 备

 

Construction 

Preparation

材料计划、材料送审、施工方案
Material   plan,   material   review 

and approval, and construction 
program

认真编制
Work out carefully

明管安装
Open–pipe 
installation

位置、标高正确、接地良好
The position and elevation are 
correct,   and   the   grounding   is 

good

绘制综合图及管路接地大样图
Draw integrated drawing and 
detail of pipeline grounding

桥架线槽安装
Installation 
on

 

crane 

span 
structure slot

标高准确、吊架安装、穿墙、楼板的防
火处理、与其它专业管道的间距
Correct   level,   installation   on 
hanger   frame,   fire   protection 

treatment   of   through-wall   and 
floor,   clearance   with   other 

special pipeline

绘制综合图、吊架安装图、防火处
理大样图
Draw   integrated   drawing, 
installation   drawing   of 

hanger   frame,   and   detail   of 
fire protection treatment

穿线配线
Threading 
distribution

接线正误、导线涮锡、导线损伤
Wiring

 

correct

 

error, 

conducting   wire   with   rinsing 
tin,   conducting   wire   with 

damage

严格执行接线图、涮锡
穿线时注意保护导线
Strictly   carry   out   wiring 
drawing,   rinsing   tin,   pay 

attention   to   protecting   the 
wire when threading

电缆敷设
Cable lay

电缆平直、固定牢固、电缆弯扁度、标

Straight   cable,   firm   fixing, 
cable

 

bending,

 

and 

identification

落实图纸、规范相关要求
Implement

 

requirements 

relating   to   drawing   and 
specification

焊接点
Soldered dot

焊接部位的接地电阻、焊点表面光滑
饱满
Ground   resistance   at   welded 
position,   and   the   surface   at 

welded point is smooth and full

焊接完成后测试焊接部位的接地
电阻
Test the ground resistance of 
welded   position   after 

finishing the welding. 

器具安装
Appliance 

installation

位置正确、安装牢固、观感良好
The   position   is   correct   and 

installed

 

firmly,

 

the 

appearance is good.

按绘制的机电综合图、表面器具布
置平面图安装
Arrange  the  plan   installation 
according

 

to 

electromechanical

 

drawn 

integration   diagram   and 

surface appliance 

调试
Debugging

系统运行的稳定性、运行的可靠性、
绝缘摇测
Operating   stability,   reliability, 
and   insulating   shake-measure 

in system

制订专项调试方案
Work   out   the   special 

debugging plan

三 、 关 键 工 序 技 术 及 质 量 控 制 保 证 措

  Key Working Procedure and 

Quality Control Guarantee Measure

1、镀锌钢管明敷设  Open Lay of Galvanized Steel Pipe

本工程明敷设钢管均采用了镀锌钢管明敷设工艺。

All open-lay steel pipes in the project adopt the open-lay technology of galvanized steel pipe. 

(1)工艺流程  Technological process:

(2)可上人的吊顶内以及不封闭式竖井通道内的配管为明配管,其管路走向及支架固定均

应按明配管要求施工。

The distributing pipe in suspended ceilings that can be entered into and shaft passages that are not 

closed  is  open.  Both  its  pipeline  direction  and  support  fixture  should  construct  according  to 

requirements of open distributing pipes. 

(3)按设计要求用冷煨法把管子煨出所需的弯度,20mm 以下管径的管子用手板煨管器,

8-

41




管路明敷

管路暗敷

管内穿线

器具安装

电缆敷设

设备安装

线槽安装

防雷与接地施工

母线安装

installation 

preparation

pipe interior wire laying

instrument installation

cable laying

equipment installation

debugging

naked pipe installation

covered pipe installation

tray wire fillister

lightning-protection earth engineering

sealed bus-bar arrangement

施工准备

支吊架、弯管预制

测定盒箱及固定点位置

支吊架固定

盒箱固定

管路敷设

沉降缝处理

跨接地线

Construction 

preparation

Suspender and 

siphon prefabricated

The position of the 

mensuration box and root

Suspende

r fixation

Box fixation

Pipeline 

layout

Slot dealing

Ground line