background image

PKS-P 

Park And Shutdown Position    锁梯楼层 

1 to 64 = landing 1 to 64 

255 = disables 

Specifies Park and Shutdown position. 

 

EN-XLT 

Enable Floor Translation Table   楼层转换表 

0 = disabled 

1 = enabled 

When disabled, the OCSS assumes a 1:1 landing relationship 

between the OCSS and MCSS.  When enabled, the OCSS 

uses the floor translation table, stored in EEPROM 

 

 

2、地址表  

No. 

Symbol 

Description 

1/80 

FCCB01/80 

Front Car Call Button, Landing 01/80 

1847/1926 

FUHB01/80 

Front Up Hall Call Button, Landing 01/80 

1927/2006 

FDHB01/80 

Front Down Hall Call Button, Landing 01/ 80 

 

3、A梯参数设置 

3.1  A梯安装参数设置——

INSTALL PARAMS

 

 

3.2  A梯地址表设置——M-1-3-2  

INPUTS/OUTPUTS

 

No. 

Symbol 

Link 

Setting 

No. 

Symbol 

Link 

Setting 

FCCB01 

CAR 

08— 1 

1849 

FUHB03 

HALL 

06— 1 

FCCB02 

CAR 

08— 2 

1850 

FUHB04 

HALL 

07— 1 

FCCB03 

CAR 

08— 3 

1927 

FDHB01 

HALL 

00— 0 

FCCB04 

CAR 

08— 4 

1928 

FDHB02 

HALL 

05— 2 

FCCB05 

CAR 

09— 1 

1929 

FDHB03 

HALL 

06— 2 

1847 

FUHB01 

HALL 

04— 1 

1930 

FDHB04 

HALL 

07— 2 

1848 

FUHB02 

HALL 

05— 1 

1931 

FDHB05 

HALL 

08— 2 

 

Setting 

设定值 

Name 

Group 

单梯 

群控 

Name 

Group 

单梯 

群控 

RCB-NO 

M-1-3-1-1 

GROUP 

M-1-3-1-4 

BOTTOM 

M-1-3-1-2 

EFO-P 

M-1-3-1-6 

TOP 

M-1-3-1-2 

EFO-CK 

M-1-3-1-6 

LOBBY 

M-1-3-1-2 

PKS-P 

M-1-3-1-7