The  lead-acid  storage  battery  group  is  the  drive  power  supply  or  contingency  power 

supply  for  many

 

traffic  tools . So  the  performance  of  the  storage  battery  group  is  directly 

related to the normal running of

 

traffic tools.It is necessary to measure batteries’ parameters 

accurately and frequently in order to enhance their lives,run them reliably and ensure the 
batteries  in  the  optimal  working  states . In  the  past  the  testing  of  the  storage  batteries’ 
parameters was completed artificially.However this method has many disadvantages.It’s 
slow to test batteries artificially,the measurement precision is low,and the surroundings of 
storage battery cabin are very harmful to people’s health.So it’s very important to design a 
device which can test batteries automatically.

Because suffer environmental restrictions, request system, convenient and practical Jane 

small  on  a  single  battery  for  repair  and  routine  maintenance  of  the  design,  so  the  battery 
voltage is the system test all the way. Monitoring system based on AT89C51, its work fine 
performance,  use  agile,  low  power  consumption,  is  a  high  cost  performance  chip.  Data 
collection after the completion of the ADC0809 voltage signal selection in frequency-field on 
LCD1602, measurement data display, through MAX232 level measured transform circuit will 
the voltage upload data PC computer display, storage.

Key  Words : Single

—chip  computer ; Lead-acid  battery ; Intellectual  detection 

system;Display; communication

II