1 快冷装置的投入条件

1.1 机组打闸停机后调节级金属温度降低至 350

℃以下,允许投入汽轮机快速冷却装置。

1.2 检查确认快冷装置投入前必须具备的条件:

1.2.1 润滑油、密封油、顶轴油系统运行正常。盘车装置投入连续运行,大轴偏心度小于

0.076mm。

1.2.2 高、中、低压缸金属温度、胀差、汽缸膨胀、轴向位移表指示准确。

1.2.3 检查空冷风机、真空泵、主机轴封供汽系统停运,真空破坏门开启。

1.2.4 保留一台凝结水泵运行,低压缸喷水减温投入。

1.2.5 关闭所有高低压本体疏水一、二次门。

1.2.6 确认高排逆止阀关闭,高排逆止阀前疏水开启,开启高排通风阀。

1.2.7 低压缸人孔门开启。

1.2.8 检查供快冷气源的空压机工作正常。

1.3 快冷装置投入与停止

1.3.1 检查快冷装置阀门在关闭状态。

1.3.2 打开空气电加热器疏水门使其母管中油水排尽。

1.3.3 渐开快冷装置供汽电磁阀、串联阀,微开集气箱疏水阀使其油水进一步排尽。

1.3.4 油水排尽后、开启快冷装置供汽电磁阀、串联阀、并联阀、低温阀和集气箱疏水阀。使管

路中的杂物彻底排空,时间约

5-10 分钟后,再将以上阀门关闭。