background image

 

 

2、

  电动机频繁启动

 S

km

=S

rT

/(x

T

+S

rT

/S")=14 (MVA)

(1) 选用电机为37KW三相鼠笼异步电机(S

qM

=0.322 MVA)。

 X

l

=(0.07+6.3/185)*0.5*0.15+(0.07+6.3/25)*0.05=0.031+0.016=0.047

S

q

=1/(1/S

qM

+X

l

/U

2

m

)=0.292

 Q

fh

=0.302

 u

qm

=(S

km

+Q

fh

)/(S

km

+Q

fh

+S

q

)=14.302/14.594=0.980

u

qM

 =0.98*S

q

/S

qM

=0.98*0.292/0.322=0.89

(2) 选用电机为30KW三相鼠笼异步电机(S

qM

=0.263 MVA)。

 X

l

=(0.07+6.3/185)*0.5*0.15+(0.07+6.3/16)*0.05=0.031+0.023=0.054

 Q

fh

=0.302

S

q

=1/(1/S

qM

+X

l

/U2m)=0.239

 u

qm

=(S

km

+Q

fh

)/(S

km

+Q

fh

+S

q

)=14.302/14.541=0.984

u

qM

 =0.984*S

q

/S

qM

=0.984*0.239/0.263=0.90

故电机功率为30KW三相鼠笼异步电机可直接启动。
工厂配电设计手册150页表6-16,钢铁手册下册193页表23-4